logo
Casa ProdottiGeneratore del gas

Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing

Certificazione
La CINA Qingdao Kingway Industry Co., Ltd. Certificazioni
La CINA Qingdao Kingway Industry Co., Ltd. Certificazioni
Sono ora online in chat

Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing

Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing
Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing

Grande immagine :  Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing

Dettagli:
Luogo di origine: Cina
Marca: Kingway Power
Certificazione: CE, ISO
Numero di modello: KL280
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1 set
Prezzo: usd14,000.00
Imballaggi particolari: Custodia in legno
Tempi di consegna: 14 giorni
Termini di pagamento: L/C, T/T
Capacità di alimentazione: 20 unità al mese

Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing

descrizione
Portabilità: Portatile o stazionario Applicazione: Prova del generatore
Potenza di controllo: 380 VCA 50 Hz Capacità di carico: Varia (ad esempio, da 10 kW a 2000 kW)
Volaglità nominale: 400v Colore: Personalizzato
Dispersione di calore: Raffreddamento ad aria

Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing

Our Kingway KL2800 Intelligent Resistive and Inductive Load Banks are engineered to provide precise, heavy-duty electrical load testing for demanding generator commissioning and power system validation. By utilizing advanced automatic steps and power factor control technology, our containerized system delivers optimized, high-capacity testing across diverse power sources, ensuring exceptional operational stability, rigorous frequency response analysis, and genuine simulation of real-world site conditions.

From large-scale distributed power stations to autonomous micro-grid field deployments, this Containerized AC Power Loadcenter integrates precision digital control, robust cooling fan architectures, and intelligent remote-monitoring systems. Every unit is designed to flawlessly match complex resistive-inductive ($R&I$) testing profiles, significantly reducing diagnostic downtime while maximizing the safety and long-term reliability of your critical power infrastructure.

Technical Specifications

Feature Detailed Configuration
Rating Voltage / Frequency 380V/50Hz
Load Resolution

Resistive Load: 22 steps (1KW, 2KW, 2KW, 5KW, 10KW, 10KW, 20KW, 50KW, 100KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW)

Inductive Load: 19 steps (1KVAR, 2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR, 100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR)

Power Factor 0.8 (lag)
Load Tolerance Each step: ±5% | Overall: ±3%
Fan & Control Voltage External AC 3 phase 4 line, 380V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling "Y")

Control power input——Connector-bar

Communication Interface

RS485, RS232

Insulation / Protection

Insulation: F | Max Protection Grade: IP54

Cooling System

Cooling SystemForced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling

Enclosure & Dimension

Container type, with a ladder, air inlet and outlet with mesh enclosure and protection door


Dimensions: 6058mm × 2350mm × 2591mm 

Environment Parameter

-10+50

Brands of Main Components

Contactor: Schneider | Fuse: Miro | Alloy Resistor: KINGWAY | Data Processing Software: KINGWAY

Why Choose Our Power Systems?

  • Tailored Load Configuration: Custom-engineered resistive and inductive element steps to perfectly match specific generator testing requirements and diverse power factor  calibrations.


  • Intelligent System Integration: Full integration of high-end components—including Schneider contactors, Miro fuses, and KINGWAY proprietary alloy resistors—housed in a rugged IP54 container to ensure maximum stability under harsh outdoor environments.


  • High ROI: Highly precise digital measurement and intelligent remote-monitoring systems prevent costly testing downtime, providing fast, accurate commissioning data that shortens project payback periods.


  • Full-Lifecycle Support: Comprehensive, long-term availability of original spare parts paired with advanced KINGWAY remote technical diagnostic and data processing software services.


Primary Applications

  • Data Centers & Critical Infrastructure: Providing high-capacity, multi-step load testing for standby diesel generators and UPS systems to guarantee zero-downtime power backup.
  • Marine & Offshore Engineering: Rigorous commissioning and load verification of shipboard generators and offshore platform power plants under simulated heavy-duty sea conditions, compliant with LR/DNV/BV standards.

  • Oil & Gas Operations: Reliable on-site electrical load testing for localized micro-grids, field power stations, and turbine generators in demanding oilfields and remote drilling operations.

  • Renewable Energy & Micro-Grids: Performance validation and stress-testing of hybrid power systems, including energy storage systems (ESS), wind, solar, and biomass autonomous grids.

Frequently Asked Questions (FAQ)

Q1: How do I choose the correct generator for my gas source?

A: Gas composition and pressure are critical. Please provide a gas analysis report (including H2S content), and our engineering team will suggest the optimal model.

Q2: Can the generator operate in extreme temperatures?

A: Yes, we provide custom cooling systems, including specialized radiators or heat exchangers, for operational environments ranging from -40°C to +50°C.

Q3: How often is maintenance required?

A: Maintenance cycles depend on gas quality. We provide a tailored maintenance schedule and digital monitoring tools to track performance and predict service intervals.

Kingway 2800kW Intelligent Resistive and Inductive Load Bank Containerized AC Power Loadcenter for Generator Testing 0

Dettagli di contatto
Qingdao Kingway Industry Co., Ltd.

Persona di contatto: Mr. Bruce Jia

Telefono: +8618653247836

Fax: 86-532-55718566

Invia la tua richiesta direttamente a noi (0 / 3000)