logo
Casa ProdottiLa Banca di carico resistivo

Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

Certificazione
La CINA Qingdao Kingway Industry Co., Ltd. Certificazioni
La CINA Qingdao Kingway Industry Co., Ltd. Certificazioni
Sono ora online in chat

Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ
Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

Grande immagine :  Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

Dettagli:
Luogo di origine: Cina
Marca: Kingway
Certificazione: CE/ISO
Numero di modello: KL500
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1 unità
Prezzo: USD9900-15000/Unit
Imballaggi particolari: Casi di compensato
Tempi di consegna: 60 giorni
Termini di pagamento: L/C, T/T
Capacità di alimentazione: 100 unità ogni 60 giorni

Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

descrizione
Evidenziare:

Heavy-duty resistive load bank 500kW

,

Forced-air cooling load bank 400V

,

Resistive load bank 50/60Hz

Technical Specifications
Rated Power 500KW
Rated Voltage 400V
Load Step Respectively: 1, 2, 2, 5, 10, 20, 20, 50, 100, 100, 200 KW
Frequency 50/60HZ
Insulation Class F Class
Key Features
High-Quality Resistors Alloy Resistors
Cooling System Forced-air Cooling
Control Modes Local Manual Control or RS232/RS485
Safety Protection
Over-temperature Alarm Automatic unload and alarm when temperature is over
safety thresholds
Fan Failure Protection Machine could not load testing before power of fan is
power on
Emergency Stop User can press emergency stop button in panel to unload
immediately when load bank is abnornal while working
Short Circuit Protection The load circuit is equipped with a fuse to avoid damage
to the equipment by short-circuiting the load or excessive
current
Applications
Generator Set Testing Prevent "Wet Stacking" and perform full-load exercises
UPS & Battery Bank
Maintenance
Periodic discharge testing to verify actual capacity
Data Center Acceptance Simulate server heat and electrical loads for
comprehensive commissioning
R&D/Laboratory For performance burn-in and stress testing of power
electronics